Product Identification

Product ID:DACOM 412 G
MSDS Date:01/01/1985
FSC:6850
NIIN:00D000434
MSDS Number: BBCRN

Responsible Party
DACON(MFR),RAPICOM,INC(DIST)
1700 N MOORE ST SUITE 1000
ARLINGTON, VA 22209-1903
US

Cage: DO980

Contractor
RICOH CORP
ARLINGTON, VA 22209-1903 US

Telephone: 408-432-8800

Cage: 29068

Ingredients

MIXED ISODECANES

Fraction By Weight: 99.0%

ACGIH TLV: 400 PPM

Hazards

Effects of Overexposure:INHALATION:HEADACHE,NAUSEA,MILD
DEPRESSION,RESPIR.IRRITATION.INGESTION:UPSET
STOMACH,POSS.IRR,NAUSEA

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR.INGEST:DONT INDUCE VOMITING;CALL DR
IMMED.EYES:FLUSH W/WATER FOR 15 MIN. IF IRRITATION PERSISTS,CALL
DR.

Fire Fighting

Flash Point:102-107F TCC
Lower Limits:0.8
Upper Limits:7.0
Extinguishing Media:FOAM-TYPE EXTINGUISHER-SUPERIOR TO CO*2
EXTINGUISHERS
Fire Fighting Procedures:AVOID WATER-IT TENDS TO SPREAD HYDROCARBON
SOLVENT FIRES.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:REMOVE IGNITION SOURCES.IF AMOUNT IS
SMALL'UNDER 1 PT) ALLOW TO EVAPORATE-INCREASING AIR CIRCULATION IF
POSSIBLE-& AVOID ANY SPARKS OR OPEN FLAMES.IF AMT IS LARGE,TRY TO
COND AIR AND SOP UP INTO A CON TAINER WHICH CAN BE CLOSED.

Handling

Handling and Storage Precautions:KEEP CONTAINERS CLOSED.AVOID STORAGE
NEAR HEAT,STRONG LIGHT(IF CONTAINERS ARE CLEAR),SPARKS,OR OPEN
FLAME.
Other Precautions:AVOID USE IN A SMALL CLOSED ROOM OR CONFINED ARE
W/POOR AIR CIRCULATION.

Exposure Controls

Ventilation:MECHANICAL AS REQUIRED
Supplemental Safety and Health

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:320-350F
Vapor Pres:2.0
Vapor Density:5.0
Spec Gravity:0.747
Evaporation Rate & Reference:0.45,BUTYL ACETATE
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK,MOBILE LIQUID,FAINT HYDROCARBON ODOR.
Percent Volatiles by Volume:99+

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANT LIKE CHROMIC ACID,LIQUID CHLORINE & CONC O*2

Disposal

Waste Disposal Methods:LARGE CONTAINERS OF WASTE MUST BE HANDLED BY
PERSONS OR FIRMS WITH FACILITIES FOR DISPOSAL;FOR
EXAMPLE,CONTROLLED BURNING.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.